HE 100 2.5 kWh 100 Ah 25.2 Vdc 15.7 kg
HE 150 3.7 kWh 150 Ah 25.2 Vdc 22.4 kg
HE 200 5.0 kWh 200 Ah 25.2 Vdc 28.6 kg
HE 300 7.5 kWh 300 Ah 25.2 Vdc 41.5 kg

HE Series

HE 100 2.5 kWh 100 Ah 25.2 Vdc 15.7 kg
HE 150 3.7 kWh 150 Ah 25.2 Vdc 22.4 kg
HE 200 5.0 kWh 200 Ah 25.2 Vdc 28.6 kg
HE 300 7.5 kWh 300 Ah 25.2 Vdc 41.5 kg

System Modularity

Up to 96 Vdc

Weight & Space Saving

High Energy Density

Flexible and Scalable

System integration and scalability are the key benefits of the MG product range. Easily expand your energy storage system by connecting MG HE NMC battery modules in parallel or series. This increases the system capacity or creates systems up to 96 Vdc. Every MG energy storage system must include an MG battery management controller for safe operation. Connect multiple MG Masters in parallel to create redundancy. This increases the reliability of your battery system.

System Modularity NMC Battery

System Modularity

Up to 96 Vdc

Weight & Space Saving

High Energy Density

Flexible and Scalable

System integration and scalability are the key benefits of the MG product range. Easily expand your energy storage system by connecting MG battery modules in parallel or series. This increases the system capacity or creates systems up to 96 Vdc. Every MG energy storage system must include an MG battery management controller for safe operation. Connect multiple MG Masters in parallel to create redundancy. This increases the reliability of your battery system.

How To Install

Light Weight High Energy Density

Compact & Lightweight

Because of the high energy density, the HE-Series battery modules are suitable for lightweight applications. It is weight saving and space saving, because the battery module has compact dimensions.

High Energy Density

The HE battery series are based on a battery cell with a high energy density. This means that more energy is stored with a lower weight. As a result, more energy is available and more appliances can be powered for longer periods of time.

HE Series NMC Battery
Same footprint

Same Footprint

There are four different models in the HE battery series. This makes the HE-Series suitable for a broad range of applications, and perfect for meeting unique system requirements. All four models have the same footprint.

HE Performance

Every HE battery module consists of lithium-ion NMC battery cells. The NMC cell chemistry creates an advanced, high power cell which ensures solid performance characteristics. When replacing lead acid batteries with lithium-ion batteries, more energy storage capacity will be available whilst using the same amount of weight and space.

NMC Battery Performance

HE Performance

Every HE battery module consists of lithium-ion NMC battery cells. The NMC cell chemistry creates an advanced, high power cell which ensures solid performance characteristics. When replacing lead acid batteries with lithium-ion batteries, more energy storage capacity will be available whilst using the same amount of weight and space.

Safety ++

Battery Management System

To ensure a high safety standard, each battery module comes with an integrated battery management system. This is an intelligent electronic module called a slave BMS.  This slave BMS measures all cell voltages and temperatures inside the battery module. It controls balancing on both cell and module level, which is unique in the market. The slave BMS in each battery module communicates with a Master BMS. Via a galvanically isolated CAN-Bus the MG Master collects and monitors the status of all battery modules. If the measured values from a battery module exceed the limit, the MG Master will automatically take action to protect all of the connected battery modules.

CAN-Bus HE series

Safety ++

Battery Management System

To ensure a high safety standard, each battery module comes with an integrated battery management system. This is an intelligent electronic module called a slave BMS.  This slave BMS measures all cell voltages and temperatures inside the battery module. It controls balancing on both cell and module level, which is unique in the market. The slave BMS in each battery module communicates with a Master BMS. Via a galvanically isolated CAN-Bus the MG Master collects and monitors the status of all battery modules. If the measured values from a battery module exceed the limit, the MG Master will automatically take action to protect all of the connected battery modules.

Previous slide
Next slide

Application Examples

The HE battery modules are designed for use in multiple applications in mobile and off-grid markets. For example to power electric motors for hydraulic power packs or energy storage systems (ESS) for solar fields.

Previous slide
Next slide

Application Examples

The HE battery modules are designed for use in multiple applications in mobile and off-grid markets. For example to power electric motors for hydraulic power packs or energy storage systems (ESS) for solar fields.

Product Features

HE_Series_Product_Features_FS

Protection Cover

The protection covers serve as a shield for the cabling of the batteries. This way the chance of damaging the connections is limited. In addition, the battery poles are covered which increases the product safety.

1 of 3

Handles

To make the system installation easier, all MG batteries are equiped  with handles. The handles make the positioning of the batteries easier.

2 of 3
Metal Housing
The robust metal housing of the MG batteries makes the product more solid. In addition, a metal enclosure serves as a strong EMC radiation protection. The High Energy Density NMC batteries are impact resistant and safe to install with brackets or straps.
3 of 3
NMC Battery Product features

Protection Cover

The protection covers serve as a shield for the cabling of the batteries. This way abuse of the connections is limited.
Besides, the battery poles are covered which increases the product safety.

1 of 3

Handles

To make the system installation easier, all MG batteries contain handles. With the handles, the positioning of the batteries becomes easier.

2 of 3

Metal Housing
The robust metal housing of the MG batteries makes the product more solid. In addition, a metal enclosure serves as a strong EMC radiation protection. The High Energy Density NMC batteries are impact resistant and safe to install with brackets or straps.

3 of 3

Product Features

Technical Specifications

HE-100 Specifications

MG HE 100
25.2 V / 100 Ah

Technology Lithium-Ion NMC Battery
Nominal voltage 25.2 V
Nominal capacity 100 Ah
Nominal energy 2.5 kWh
Weight 15.7 kg
Technical specifications MG HE Battery 25.2V / 100Ah / 2500Wh – MGHE240100 MG HE Battery 25.2V / 100Ah / 2500Wh (M12) – MGHE242100
Technology Lithium-Ion NMC
Cell configuration 7S32P
Nominal voltage 25.2 V
Nominal capacity 100 Ah
Nominal energy 2.5 kWh
Specific energy 1 159 Wh/kg
Weight 15.7 kg
Cycle life 2
DOD 75 % – Economic mode 3000
DOD 95 % – Performance mode 2000
Discharge 6
Discharge cut-off voltage 21.0 V
Recommended discharge current 30 A (0.3 C)
Maximum discharge current 100 A (1.0 C)
Peak discharge current 3 200 A (2.0 C)
Internal fuses 4 150 A
Charge 6
Maximum charge voltage 29.4 V
Recommended charge current 30 A (0.3 C)
Maximum charge current 100 A (1.0 C)
Peak charge current 3 150 A (1.5 C)
Configuration
Series configuration Yes, up to 6. More on request.
Parallel configuration Yes, unlimited
Redundant mode Yes, Using multiple Master BMSs
Environmental
Operating temperature charge 0 to +45°C
Operating temperature discharge -20 to +55°C’
Storage temperature -20 to +45°C’
Humidity (non-condensing) ≤ 75 %
Mechanical
Power connections M8 stud, max. 20 Nm
Humidity (non-condensing) IP20
Cooling Air, forced (2x fan inside)
Dimensions ( l x w x h ) 366x214x193 mm
Safety
Battery Management System Integrated slave BMS
Balancing Passive
Compatible BMS master MG Master LV, MG Master HV 5
Communication CAN-Bus ( RJ45 or M12 connection)
Standards
EMC: Emission EN-IEC 61000-6-3:2007/A1:2011/C11:2012
EMC: Immunity EN-IEC 61000-6-1:2007
Low voltage directive EN-IEC 60335-1:2012/A11:2014
Approvals IEC-EN62619, IEC-EN62620 (ES-TRIN)
HE-150 Specifications

MG HE 150
25.2 V / 150 Ah

Technology Lithium-Ion NMC Battery
Nominal voltage 25.2 V
Nominal capacity 150 Ah
Nominal energy 3.7 kWh
Weight 22.4 kg
Technical specifications MG HE Battery 25.2V / 150Ah / 3750Wh – MGHE240150 MG HE Battery 25.2V / 150Ah / 3750Wh (M12) – MGHE242150
Technology Lithium-Ion NMC
Cell configuration 7S48P
Nominal voltage 25.2 V
Nominal capacity 150 Ah
Nominal energy 3.7 kWh
Specific energy 1 167 Wh/kg
Weight 22.4 kg
Cycle life 2
DOD 75 % – Economic mode 3000
DOD 95 % – Performance mode 2000
Discharge 6
Discharge cut-off voltage 21.0 V
Recommended discharge current 45 A (0.3 C)
Maximum discharge current 150 A (1.0 C)
Peak discharge current 3 300 A (2.0 C)
Internal fuses 4 250 A
Charge 6
Maximum charge voltage 29.4 V
Recommended charge current 45 A (0.3 C)
Maximum charge current 150 A (1.0 C)
Peak charge current 3 225 A (1.5 C)
Configuration
Series configuration Yes, up to 6. More on request.
Parallel configuration Yes, unlimited
Redundant mode  Yes, Using multiple Master BMSs
Environmental
Operating temperature charge 0 to +45°C
Operating temperature discharge -20 to +55°C’
Storage temperature ‘-20 to +45°C’
Humidity (non-condensing) ≤ 75 %
Mechanical
Power connections M8 stud, max. 20 Nm
Humidity (non-condensing) IP20
Cooling Air, forced (2x fan inside)
Dimensions ( l x w x h ) 366x284x193 mm
Safety
Battery Management System Integrated slave BMS
Balancing Passive
Compatible BMS master MG Master LV, MG Master HV 5
Communication CAN-Bus ( RJ45 or M12 connection)
Standards
EMC: Emission EN-IEC 61000-6-3:2007/A1:2011/C11:2012
EMC: Immunity EN-IEC 61000-6-1:2007
Low voltage directive EN-IEC 60335-1:2012/A11:2014
Approvals IEC-EN62619, IEC-EN62620 (ES-TRIN)
HE-200 Specifications

MG HE 200
25.2 V / 200 Ah

Technology Lithium-Ion NMC Battery
Nominal voltage 25.2 V
Nominal capacity 200 Ah
Nominal energy 5.0 kWh
Weight 28.6 kg
Technical specifications MG HE Battery 25.2V / 200Ah / 5000Wh – MGHE240200 MG HE Battery 25.2V / 200Ah / 5000Wh (M12) – MGHE242200
Technology Lithium-Ion NMC
Cell configuration 7S64P
Nominal voltage 25.2 V
Nominal capacity 200 Ah
Nominal energy 5.0 kWh
Specific energy 1 175 Wh/kg
Weight 28.6 kg
Cycle life 2
DOD 75 % – Economic mode 3000
DOD 95 % – Performance mode 2000
Discharge 6
Discharge cut-off voltage 21.0 V
Recommended discharge current 60 A (0.3 C)
Maximum discharge current 200 A (1.0 C)
Peak discharge current 3 400 A (2.0 C)
Internal fuses 4 300 A
Charge 6
Maximum charge voltage 29.4 V
Recommended charge current 60 A (0.3 C)
Maximum charge current 200 A (1.0 C)
Peak charge current 3 300 A (1.5 C)
Configuration
Series configuration Yes, up to 6. More on request.
Parallel configuration Yes, unlimited
Redundant mode  Yes, Using multiple Master BMSs
Environmental
Operating temperature charge 0 to +45°C
Operating temperature discharge -20 to +55°C’
Storage temperature ‘-20 to +45°C’
Humidity (non-condensing) ≤ 75 %
Mechanical
Power connections M8 stud, max. 20 Nm
Humidity (non-condensing) IP20
Cooling Air, forced (2x fan inside)
Dimensions ( l x w x h ) 366x355x193 mm
Safety
Battery Management System Integrated slave BMS
Balancing Passive
Compatible BMS master MG Master LV, MG Master HV 5
Communication CAN-Bus ( RJ45 or M12 connection)
Standards
EMC: Emission EN-IEC 61000-6-3:2007/A1:2011/C11:2012
EMC: Immunity EN-IEC 61000-6-1:2007
Low voltage directive EN-IEC 60335-1:2012/A11:2014
Approvals IEC-EN62619, IEC-EN62620 (ES-TRIN)
HE-300 Specifications

MG HE 300
25.2 V / 300 Ah

Technology Lithium-Ion NMC Battery
Nominal voltage 25.2 V
Nominal capacity 300 Ah
Nominal energy 7.5 kWh
Weight 41.5 kg
Technical specifications  MG HE Battery 25.2V / 300Ah / 7500Wh – MGHE240300 MG HE Battery 25.2V / 300Ah / 7500Wh (M12) – MGHE242300
Technology Lithium-Ion NMC
Cell configuration 7S96P
Nominal voltage 25.2 V
Nominal capacity 300 Ah
Nominal energy 7.5 kWh
Specific energy 1 182 Wh/kg
Weight 41.5 kg
Cycle life 2
DOD 75 % – Economic mode 3000
DOD 95 % – Performance mode 2000
Discharge 6
Discharge cut-off voltage 21.0 V
Recommended discharge current 60 A (0.2 C)
Maximum discharge current 210 A (0.7 C)
Peak discharge current 3 450 A (1.5 C)
Internal fuses 4 300 A
Charge 6
Maximum charge voltage 29.4 V
Recommended charge current 60 A (0.2 C)
Maximum charge current 210 A (0.7 C)
Peak charge current 3 300 A (1.0 C)
Configuration
Series configuration Yes, up to 6. More on request.
Parallel configuration Yes, unlimited
Redundant mode  Yes, Using multiple Master BMSs
Environmental
Operating temperature charge 0 to +45°C
Operating temperature discharge -20 to +55°C
Storage temperature ‘-20 to +45°C’
Humidity (non-condensing) ≤ 75 %
Mechanical
Power connections M8 stud, max. 20 Nm
Humidity (non-condensing) IP40
Cooling Air, convection (no fans)
Dimensions ( l x w x h ) 366x497x193 mm
Safety
Battery Management System Integrated slave BMS
Balancing Passive
Compatible BMS master MG Master LV, MG Master HV 5
Communication CAN-Bus ( RJ45 or M12 connection)
Standards
EMC: Emission EN-IEC 61000-6-3:2007/A1:2011/C11:2012
EMC: Immunity EN-IEC 61000-6-1:2007
Low voltage directive EN-IEC 60335-1:2012/A11:2014
Approvals IEC-EN62619, IEC-EN62620 (ES-TRIN)

Footnotes
1 Including BMS and enclosure.

2 End-of-Life is 70% of initial capacity at 25 °C. Cycle life is depending on the battery temperature. Higher
battery temperature will result in lower number of cycles.

3
Duration is depending on battery temperature.

4 Fuses can be replaced with dummy fuses for high power and high voltage applications. In this case the batteries need to be fused elsewhere in the circuit.
5 For systems >144 V, order the M12, HV version.

6 Charge and discharge rates depending on battery temperature and State-Of-Charge.